summary refs log tree commit diff stats
path: root/docs/system/devices/nvme.rst
diff options
context:
space:
mode:
Diffstat (limited to 'docs/system/devices/nvme.rst')
-rw-r--r--docs/system/devices/nvme.rst24
1 files changed, 14 insertions, 10 deletions
diff --git a/docs/system/devices/nvme.rst b/docs/system/devices/nvme.rst
index bff72d1c24..a1c0db01f6 100644
--- a/docs/system/devices/nvme.rst
+++ b/docs/system/devices/nvme.rst
@@ -110,28 +110,32 @@ multipath I/O.
 This will create an NVM subsystem with two controllers. Having controllers
 linked to an ``nvme-subsys`` device allows additional ``nvme-ns`` parameters:
 
-``shared`` (default: ``off``)
+``shared`` (default: ``on`` since 6.2)
   Specifies that the namespace will be attached to all controllers in the
-  subsystem. If set to ``off`` (the default), the namespace will remain a
-  private namespace and may only be attached to a single controller at a time.
+  subsystem. If set to ``off``, the namespace will remain a private namespace
+  and may only be attached to a single controller at a time. Shared namespaces
+  are always automatically attached to all controllers (also when controllers
+  are hotplugged).
 
 ``detached`` (default: ``off``)
   If set to ``on``, the namespace will be be available in the subsystem, but
-  not attached to any controllers initially.
+  not attached to any controllers initially. A shared namespace with this set
+  to ``on`` will never be automatically attached to controllers.
 
 Thus, adding
 
 .. code-block:: console
 
    -drive file=nvm-1.img,if=none,id=nvm-1
-   -device nvme-ns,drive=nvm-1,nsid=1,shared=on
+   -device nvme-ns,drive=nvm-1,nsid=1
    -drive file=nvm-2.img,if=none,id=nvm-2
-   -device nvme-ns,drive=nvm-2,nsid=3,detached=on
+   -device nvme-ns,drive=nvm-2,nsid=3,shared=off,detached=on
 
-will cause NSID 1 will be a shared namespace (due to ``shared=on``) that is
-initially attached to both controllers. NSID 3 will be a private namespace
-(i.e. only attachable to a single controller at a time) and will not be
-attached to any controller initially (due to ``detached=on``).
+will cause NSID 1 will be a shared namespace that is initially attached to both
+controllers. NSID 3 will be a private namespace due to ``shared=off`` and only
+attachable to a single controller at a time. Additionally it will not be
+attached to any controller initially (due to ``detached=on``) or to hotplugged
+controllers.
 
 Optional Features
 =================